Plumbing Pipe Size Calculator

Check supply pipe size against demand, pressure available and the length the water has to travel.

Your numbers

Result

Internal diameter needed 0.8 Inches
Nominal pipe size 3/4 Inches
Design velocity 8.0 Feet per second
Velocity in the chosen size 8.0 Feet per second
12 GPM at 8.0 ft/s needs 0.8 inches of bore, so use 3/4 inch pipe, which runs at 8.0 ft/s.

Pipe sizing, venting and drainage are set by the plumbing code adopted where you are, and the IPC and UPC do not agree with each other. Treat this as a planning figure and size the finished design from the code table your inspector works to. Velocity sizing ignores friction loss along the run and through fittings, which on a long or convoluted run is what actually limits flow. Hot water is held to a lower velocity because erosion corrosion attacks copper faster at temperature.

Get a Free Business Audit

What moves the number

  • Static pressure at the meter and how much of it the run consumes.
  • Total developed length, where fittings often contribute more than the straight pipe.
  • Simultaneous demand rather than total fixture count.

Where this one goes wrong

Sizing the main correctly and ignoring the branches. A correctly sized trunk feeding undersized branches still produces poor flow at the fixture, which is what the customer actually experiences.

Questions

About this calculator

Why does my flow drop when two fixtures run?

Because the pipe is sized for one. Simultaneous demand is what sizing has to cover, and a system that performs well with a single outlet open can fail entirely with two.

How much does elevation cost in pressure?

Roughly 0.433 psi for every foot of rise. On a multi-storey building that is a substantial share of the available pressure before any friction loss is counted.

Do fittings really matter that much?

On a run with many elbows and tees, yes. Their equivalent length can exceed the straight pipe, and a calculation that counts only the pipe comes out undersized.

How useful was this calculator?

Not rated yet. Yours would be the first.

The formula

pipe area = GPM / (448.8 x velocity in ft/s); diameter = sqrt(4 x area / pi)

Put this calculator on your site

Free to embed. Paste this where you want it to appear. It stays up to date automatically because it loads from BDEVY.

Please keep the attribution line. It is the only thing we ask in return.

How to use this calculator

  1. Flow required (GPM). Enter your own figure; the page starts at 12.
  2. Pipe run. Enter your own figure; the page starts at Branch, cold (8 ft/s).
  3. Material. Enter your own figure; the page starts at Copper type L.

The result updates as you type, so you can try a figure, see what it does to internal diameter needed, and change it back. Nothing you enter is sent anywhere or saved.

A worked example

These are the figures the calculator opens with. Every number in the results column below is produced by the same calculation the page runs, so you can follow it through before putting your own figures in.

What goes in

InputValue
Flow required (GPM)12
Pipe runBranch, cold (8 ft/s)
MaterialCopper type L

What comes out

ResultValue
Internal diameter needed main result0.8
Nominal pipe size3/4
Design velocity8.0
Velocity in the chosen size8.0

12 GPM at 8.0 ft/s needs 0.8 inches of bore, so use 3/4 inch pipe, which runs at 8.0 ft/s.

How sensitive the answer is

Holding everything else steady and changing only flow required (gpm), this is what happens to internal diameter needed. It is worth knowing which of your inputs the answer actually hinges on, and which barely move it.

Flow required (GPM)Internal diameter needed
6 0.6
9 0.7
12 example above 0.8
18 1.0
24 1.1

Every other input is held at the example value while this one changes, which is not how a real job behaves. Treat it as a guide to which number matters most, not as five separate quotes.

What each figure means

Flow required (GPM)
A number, between 0 and 2000, starting at 12.
Pipe run
Choose from Service main (8 ft/s), Branch, cold (8 ft/s), Hot water (5 ft/s, erosion limit), Keep it quiet (4 ft/s).
Material
Choose from Copper type L, PEX, CPVC.

What the results tell you

ResultWhat it is
Internal diameter neededThe headline result. A decimal figure.
Nominal pipe sizeA category or planning selection, rather than a measured quantity.
Design velocityA decimal figure.
Velocity in the chosen sizeA decimal figure.

Before you rely on this number

Pipe sizing, flow and pressure figures depend on the actual fittings, the run, the material and local code. Code requirements vary by jurisdiction and override any general calculation, so check what applies where the work is happening.

Estimating is the easy part

The jobs you never hear about cost more than the ones you mis-measure. BDEVY builds the marketing, systems and automation that bring them in.