Get a planning figure for the BTU a space needs, as a sanity check against a proper load calculation rather than a substitute for one.
Result
This is a preliminary sizing estimate using industry rules of thumb. Actual equipment selection requires a room-by-room load calculation (ACCA Manual J) and duct design (Manual D) by a qualified professional, oversized equipment short-cycles, dehumidifies poorly and fails early.
Get a Free Business AuditWhat moves the number
- Insulation and air sealing, which change the answer more than floor area does.
- Window area and orientation, since solar gain through west-facing glass is substantial.
- Ceiling height, because the load follows volume rather than square footage.
- Climate zone and design temperature, which set the conditions the system has to hold.
Where this one goes wrong
Treating a square footage rule as a design. It is a starting point and nothing more. A Manual J load calculation accounts for construction, orientation, infiltration and internal gains, and equipment selected without one is guessed at.
Before you quote
- Whether the ductwork can carry the airflow the equipment needs.
- Whether existing insulation matches what the figure assumes.
- Whether the load is driven by cooling or heating in this climate.
Questions
About this calculator
Is a BTU rule of thumb good enough to size equipment?
No. It is useful as a sanity check against a load calculation, and it will tell you quickly if a proposed unit is wildly wrong. Selecting equipment from it is how systems get oversized.
Why is oversizing a problem?
An oversized system satisfies the thermostat quickly and shuts off, which means short run times, poor dehumidification and more wear from cycling. The house reaches temperature and still feels clammy.
What actually changes the load most?
The building envelope. Insulation, air sealing and glazing move the number far more than floor area, which is exactly what a square footage rule cannot see.
The formula
base BTU = area × 20, then adjusted for ceiling height, sun, occupants and room type
Put this calculator on your site
Free to embed. Paste this where you want it to appear. It stays up to date automatically because it loads from BDEVY.
Please keep the attribution line. It is the only thing we ask in return.
How to use this calculator
- Room area (sq ft) (sq ft). Enter your own figure; the page starts at 400 sq ft.
- Ceiling height (ft) (ft). Enter your own figure; the page starts at 8 ft.
- Sun exposure. Enter your own figure; the page starts at Average.
- Regular occupants. Enter your own figure; the page starts at 2.
- Room type. Enter your own figure; the page starts at Living space.
The result updates as you type, so you can try a figure, see what it does to cooling capacity needed, and change it back. Nothing you enter is sent anywhere or saved.
A worked example
These are the figures the calculator opens with. Every number in the results column below is produced by the same calculation the page runs, so you can follow it through before putting your own figures in.
What goes in
| Input | Value |
|---|---|
| Room area (sq ft) | 400 sq ft |
| Ceiling height (ft) | 8 ft |
| Sun exposure | Average |
| Regular occupants | 2 |
| Room type | Living space |
What comes out
| Result | Value |
|---|---|
| Cooling capacity needed main result | 8,000 |
| In tons | 0.7 |
| In kilowatts | 2.3 |
| Base capacity before adjustments | 8,000 |
This room needs roughly 8,000 BTU/h of cooling, about 0.7 tons, or 2.3 kW.
How sensitive the answer is
Holding everything else steady and changing only room area (sq ft), this is what happens to cooling capacity needed. It is worth knowing which of your inputs the answer actually hinges on, and which barely move it.
| Room area (sq ft) (sq ft) | Cooling capacity needed |
|---|---|
| 200 sq ft | 4,000 |
| 300 sq ft | 6,000 |
| 400 sq ft example above | 8,000 |
| 600 sq ft | 12,000 |
| 800 sq ft | 16,000 |
Every other input is held at the example value while this one changes, which is not how a real job behaves. Treat it as a guide to which number matters most, not as five separate quotes.
What each figure means
- Room area (sq ft) (sq ft)
- Measured in sq ft, starting at 400 sq ft.
- Ceiling height (ft) (ft)
- Measured in ft, between 0 and 30, starting at 8 ft.
- Sun exposure
- Choose from Heavily shaded, Average, Very sunny.
- Regular occupants
- A number, between 0 and 100, starting at 2.
- Room type
- Choose from Living space, Kitchen, Bedroom.
What the results tell you
| Result | What it is |
|---|---|
| Cooling capacity needed | The headline result. A number. |
| In tons | A decimal figure. |
| In kilowatts | A decimal figure. |
| Base capacity before adjustments | A number. |
Before you rely on this number
Sizing, capacity and load figures here are planning estimates. A real installation depends on the manufacturer's data for the specific equipment, the duct system it is going into, and a proper load calculation for the building. Use this to sanity-check a number or price a job, not to select equipment.
Keep going
Related calculators
AC Size Calculator
Estimate cooling capacity for a space as a cross-check on a load calculation, not as a replacement for one.
Open calculatorHVAC Load Calculator
Produce a planning load figure from the envelope and climate, as preparation for a proper Manual J rather than a substitute.
Open calculatorCFM Calculator
Work out the airflow a space or a system needs, and check it against what the equipment and ducts can actually deliver.
Open calculatorEstimating is the easy part
The jobs you never hear about cost more than the ones you mis-measure. BDEVY builds the marketing, systems and automation that bring them in.