Electrical Load Calculator

Build an early dwelling-load estimate from floor area and major appliances, then identify what a formal service calculation still needs.

Your numbers

sq ft
Kitchen circuits, minimum two required.

Result

Suggested service size 150 A service
Calculated load 121.4 Amps
Demand load after derating 29,125 Watts
Total connected load 34,000 Watts
Demand load is about 29,125 W, or 121.4 amps at 240 V, pointing to a 150 A service.

Electrical work is life-safety work governed by the NEC or your local code, and must be designed and installed by a licensed electrician. Conductor and overcurrent sizing depends on ambient temperature, conductor bundling, termination ratings, continuous-load rules and more. This is an educational estimate and must never be used as the basis for an installation. This follows the shape of the NEC Article 220 standard method but simplifies it considerably: range demand factors, dryer minimums, largest-motor rules and the optional calculation method all change the result. A licensed electrician must perform the actual load calculation.

Get a Free Business Audit

What moves the number

  • Floor area and the entered appliance loads establish the connected-load starting point.
  • Demand assumptions differ from simply adding every nameplate.
  • Heating, cooling and planned additions affect the load schedule that needs review.

Where this one goes wrong

This simplified model omits parts of a complete dwelling calculation. A suggested service size is not approval to add an EV charger or replace a service. Spare panel spaces and unused amperage are different questions.

Questions

About this calculator

Why is demand lower than connected load?

Demand methods recognize that specified loads are not all assessed identically. The permissible method and its conditions must come from the adopted code, rather than an arbitrary diversity discount.

Can my utility bill establish service capacity?

Energy consumed over a billing period does not reveal every coincident peak. Approved demand records and a formal load assessment answer different questions.

Does this replace an electrician's calculation?

No. It is a planning check for a code-governed design, with appliance details, local amendments and utility requirements still to resolve.

How useful was this calculator?

Not rated yet. Yours would be the first.

The formula

general lighting = 3 VA per sq ft; first 3,000 VA at 100%, remainder at 35%; plus appliance and HVAC loads

Put this calculator on your site

Free to embed. Paste this where you want it to appear. It stays up to date automatically because it loads from BDEVY.

Please keep the attribution line. It is the only thing we ask in return.

How to use this calculator

  1. Floor area (sq ft) (sq ft). Enter your own figure; the page starts at 2,000 sq ft.
  2. Small-appliance circuits. Kitchen circuits, minimum two required.
  3. Range / cooktop (watts). Enter your own figure; the page starts at 8,000.
  4. Dryer (watts). Enter your own figure; the page starts at 5,000.
  5. HVAC (watts). Enter your own figure; the page starts at 6,000.
  6. Other fixed appliances (watts). Enter your own figure; the page starts at 4,500.

The result updates as you type, so you can try a figure, see what it does to suggested service size, and change it back. Nothing you enter is sent anywhere or saved.

A worked example

These are the figures the calculator opens with. Every number in the results column below is produced by the same calculation the page runs, so you can follow it through before putting your own figures in.

What goes in

InputValue
Floor area (sq ft)2,000 sq ft
Small-appliance circuits2
Range / cooktop (watts)8,000
Dryer (watts)5,000
HVAC (watts)6,000
Other fixed appliances (watts)4,500
Service voltage (V)240

What comes out

ResultValue
Suggested service size main result150 A service
Calculated load121.4
Demand load after derating29,125
Total connected load34,000

Demand load is about 29,125 W, or 121.4 amps at 240 V, pointing to a 150 A service.

How sensitive the answer is

Holding everything else steady and changing only floor area (sq ft), this is what happens to suggested service size. It is worth knowing which of your inputs the answer actually hinges on, and which barely move it.

Floor area (sq ft) (sq ft)Suggested service size
1,000 sq ft 150 A service
1,500 sq ft 150 A service
2,000 sq ft example above 150 A service
3,000 sq ft 150 A service
4,000 sq ft 150 A service

Every other input is held at the example value while this one changes, which is not how a real job behaves. Treat it as a guide to which number matters most, not as five separate quotes.

What each figure means

Floor area (sq ft) (sq ft)
Measured in sq ft, starting at 2,000 sq ft.
Small-appliance circuits
Kitchen circuits, minimum two required.
Range / cooktop (watts)
A number, between 0 and 100000, starting at 8,000.
Dryer (watts)
A number, between 0 and 100000, starting at 5,000.
HVAC (watts)
A number, between 0 and 200000, starting at 6,000.
Other fixed appliances (watts)
A number, between 0 and 200000, starting at 4,500.
Service voltage (V)
A number, between 0 and 1000, starting at 240.

What the results tell you

ResultWhat it is
Suggested service sizeThe headline result. A category or planning selection, rather than a measured quantity.
Calculated loadA decimal figure.
Demand load after deratingA number.
Total connected loadA number.

Before you rely on this number

Conductor sizing, voltage drop and load figures are governed by code, and the code takes precedence over any calculator. Ambient temperature, conduit fill, continuous load factors and the specific installation all change the answer. Treat this as a first pass, not a design.

Estimating is the easy part

The jobs you never hear about cost more than the ones you mis-measure. BDEVY builds the marketing, systems and automation that bring them in.