Tankless Water Heater Size Calculator

Size a tankless unit from temperature rise and simultaneous flow, which is where most undersizing happens.

Your numbers

Add the fixtures that realistically run together.
F
F
%

Result

Breaker size needed 0 Amps, electric only, at 125%
Gas input needed 171,196 BTU per hour, gas only
Temperature rise needed 70.0 Degrees F
Input required 171,196 BTU per hour
If electric 46.2 Kilowatts
Electric current at 240 V 0.0 Amps
Raising 4.5 GPM by 70.0 degrees needs about 171,196 BTU/h, which usually means a dedicated gas line larger than the one feeding a storage heater.

Tankless capacity falls in winter because the incoming water is colder and the required rise is larger. Size on the coldest month, not an annual average. Gas units usually need a larger gas line and a different vent; electric units often need service capacity a typical house does not have.

Get a Free Business Audit

What moves the number

  • Temperature rise required, which is the gap between incoming and delivered temperature.
  • Simultaneous flow in gallons per minute, not total fixture count.
  • Incoming water temperature in the coldest month, which is the design case.

Where this one goes wrong

Sizing on a summer temperature rise. The unit that delivers two showers in August may manage one in February, and the customer calls in winter. Size to the coldest incoming temperature.

Before you quote

  • Whether the gas line and meter can supply the input, which is often far larger than a tank unit.
  • Whether the venting required is available or achievable.
  • For electric units, whether the electrical service can carry the load at all.

Questions

About this calculator

Why do tankless units disappoint in winter?

Because capacity is expressed as flow at a given temperature rise. Colder incoming water means a larger rise, and the same unit delivers considerably less flow at the temperature the customer wants.

Does a tankless unit need a bigger gas line?

Very often. The input rating is much higher than a storage heater, and an existing line sized for a tank frequently cannot supply it. That check belongs in the quote, not in the installation.

Is electric tankless a straight swap?

Rarely. Whole-house electric tankless draws heavily and commonly needs a service upgrade, which can cost more than the unit. Confirm the electrical capacity before quoting.

How useful was this calculator?

Not rated yet. Yours would be the first.

The formula

BTU/h = GPM x temperature rise x 500, divided by efficiency

Put this calculator on your site

Free to embed. Paste this where you want it to appear. It stays up to date automatically because it loads from BDEVY.

Please keep the attribution line. It is the only thing we ask in return.

How to use this calculator

  1. Flow needed at once (GPM). Add the fixtures that realistically run together.
  2. Incoming water temperature (F) (F). Enter your own figure; the page starts at 50 F.
  3. Hot water temperature (F) (F). Enter your own figure; the page starts at 120 F.
  4. Fuel. Enter your own figure; the page starts at Gas.
  5. Efficiency (%). Enter your own figure; the page starts at 92%.

The result updates as you type, so you can try a figure, see what it does to temperature rise needed, and change it back. Nothing you enter is sent anywhere or saved.

A worked example

These are the figures the calculator opens with. Every number in the results column below is produced by the same calculation the page runs, so you can follow it through before putting your own figures in.

What goes in

InputValue
Flow needed at once (GPM)4.5
Incoming water temperature (F)50 F
Hot water temperature (F)120 F
FuelGas
Efficiency92%

What comes out

ResultValue
Breaker size needed0
Gas input needed171,196
Temperature rise needed main result70.0
Input required171,196
If electric46.2
Electric current at 240 V0.0

Raising 4.5 GPM by 70.0 degrees needs about 171,196 BTU/h, which usually means a dedicated gas line larger than the one feeding a storage heater.

How sensitive the answer is

Holding everything else steady and changing only flow needed at once (gpm), this is what happens to temperature rise needed. It is worth knowing which of your inputs the answer actually hinges on, and which barely move it.

Flow needed at once (GPM)Temperature rise needed
2.25 70.0
3.38 70.0
4.5 example above 70.0
6.75 70.0
9 70.0

Every other input is held at the example value while this one changes, which is not how a real job behaves. Treat it as a guide to which number matters most, not as five separate quotes.

What each figure means

Flow needed at once (GPM)
Add the fixtures that realistically run together.
Incoming water temperature (F) (F)
Measured in F, between 33 and 80, starting at 50 F.
Hot water temperature (F) (F)
Measured in F, between 90 and 160, starting at 120 F.
Fuel
Choose from Gas, Electric.
Efficiency (%)
A percentage, between 0 and 100, starting at 92%.

What the results tell you

ResultWhat it is
Breaker size neededA number.
Gas input neededA number.
Temperature rise neededThe headline result. A decimal figure.
Input requiredA number.
If electricA decimal figure.
Electric current at 240 VA decimal figure.

Before you rely on this number

Pipe sizing, flow and pressure figures depend on the actual fittings, the run, the material and local code. Code requirements vary by jurisdiction and override any general calculation, so check what applies where the work is happening.